Wafer Lock Reading Goes High Tech

Keedex has something new for reading wafer locks - a method of determining the depths of cut without removing or disassembling a lock. The Keedex USB Wafer Reader is a specialty digital camera that connects to a computer to provide an image of the lock...


To access the remainder of this piece of premium content, you must be registered with Locksmith Ledger. Already have an account? Login

Register in seconds by connecting with your preferred Social Network.

OR

Complete the registration form.

Required
Required
Required
Required
Required
Required
Required
Required
Optional
Required
Required

Keedex has something new for reading wafer locks - a method of determining the depths of cut without removing or disassembling a lock. The Keedex USB Wafer Reader is a specialty digital camera that connects to a computer to provide an image of the lock face, keyway and the ledge positions of the wafers. Having a large image makes reading the wafer tumblers much easier. In addition, still and video images can be saved for comparison and future reference.

The Keedex Wafer Reader adjustable focal length camera resolution is two mega pixels. Because the Wafer Reader is an electronic device, the magnification is dependent upon the size of the display. The larger the display, the greater the apparent magnification is. Magnification using a 17” monitor is approximately 150X. The resolution of this camera’s images is 640 wide by 480 high pixels and the image size is 8.889” by 6.667” at 72 dots per inch. When shooting video, the display speed is 30 frames per second, which is the video standard in the United States.

The camera is approximately five inches long and approximately ½” diameter. The camera is normally connected to a laptop or netbook computer using an attached four-foot USB cable. No additional power is required; the USB cable provides the power source. (Contact Keedex for hardware requirements.)

This lightweight video clip and still image camera is equipped with an adjustable LED for illumination and a probe assembly to locate the focal point and manipulate the object being viewed. The intensity of the LED is adjustable to provide sufficient lighting for viewing the wafer tumblers within the keyway of the lock.

Operating the camera is relatively simple. With the computer up and the software running, the display provides a magnified image. To focus the camera, place the tip of the probe against a printed page. Because of the high magnification, the focal point is very small and must be accurately set. A printed page provides good contrast in order to have an image that is very sharp. Adjust the focus screw on the rear of the camera while viewing the image on the computer screen. The camera is in adjustment when the image of the print edge is sharp.

This way the camera’s focal length is set at the tip of a probe. When reading the wafers, place the tip of a probe against each wafer being read. A probe is secured to the camera assembly using two setscrews. To change a probe, use a 1/8” hex wrench. Always adjust the focal length after changing to a different probe.

The camera is equipped with an LED (Light Emitting Diode) whose intensity can be adjusted to maximize viewing. An adjustment wheel for the LED is built into the USB cable. Once the camera is in focus, insert the probe into the keyway and adjust the LED in order to read the wafer tumblers.

When reading the wafer tumblers, there are several important points to consider. Most importantly, the lock must be securely attached. If the lock can be shifted, the wafers can be more difficult to keep in focus.

Another important point is to know the lock. How many wafers are in the lock? How many depths of cut? Do some or all of the wafers have a number stamped into the face? The number will most often be stamped above the window. Is the lock single throw, meaning all of the wafers move in the same direction, or is the lock double throw, where adjacent wafers move in opposite directions? If the lock is double throw, the likelihood is half of the wafers that have a depth of cut stamped will not be visible as the wafers are positioned 180 degrees to accommodate their springs.

To read a wafer lock, place the probe into the keyway. If the lock is equipped with a shutter unit, use a turning tool to keep the shutter open. Use a pick to determine that the number of wafers in the lock agrees with the manufacturer’s information.