Installing the SARGENT PROFILE SERIES using the Major Manufacturing HIT-136 Drill Guide

SARGENT introduced the standalone Profile Electronic Access Control Series Locks in 2001. These electro-mechanical locks can control access electronically using keypad, Radio Frequency (RF) technology and proximity for up to 2,000 users. These locking...


Step 5. Test the operation of the mechanical lock. If the lock operates smoothly, tighten the two Phillips head screws securing the latch to the door edge.

Step 6. Remove the outside lever by inserting the operating key and rotating it clockwise 45 degrees. In this position, depress the retainer and slide off the lever and lock cylinder.

Step 7. Feed the ribbon cable (keypad harness) connector and ground wire through the 1-1/2” diameter cross bore, placing the exterior escutcheon over the lock and aligning the mounting posts.

Note: Verify the position of the cylinder spacer to locate within the cutout in the outside lever.

Step 8. Slide the outside keyed lever onto the tube.

Step 9. Rotate the key 45 degrees clockwise, and secure the lever. Test the operation of the outside lever using the key.

Step 10. Remove the battery cover from the inside escutcheon using the supplied security wrench.

Step 11. Connect the ground wire to terminal E3.

Step 12. Connect the ribbon cable to the controller connector on the upper rear of the inside escutcheon. Do not force the connector.

Step 13. Connect the lock body motor wiring to the motor connector. The motor connector is positioned vertical above the inside rose.

Tilt the upper portion of the outside escutcheon to pull the excess wiring onto the exterior side of the door. The outside escutcheon has a cavity that will accommodate the excess wiring. Make sure you do not crimp the wiring.

Step 14. Place the inside escutcheon onto the door face and secure using the two Phillips head screws.

IMPORTANT: Hand-screw the escutcheon halves together. Do not use a power screwdriver or drill/driver to tighten these screws.

Follow programming instructions to complete the installation.

For more information on the HIT-1366, contact your local locksmith wholesaler or Major Manufacturing, 1825 Via Burton, Anaheim , CA 92896 . Telephone: 714-772-5202. Fax: 714-772-2302. Web Site: www.majormfg.com.

For more information on the SARGENT Profile Series Locks, contact your local locksmith wholesaler or SARGENT Lock, 100 Sargent Drive , New Haven , CT 06511 . Telephone: 800-727-5477. Fax: 203-821-5793. Web site: www.sargentlock.com .

Photos Available Soon

01- Major Manufacturing HIT-136 Drill Guide

02- Cylindrical lock door prep (please remove background of room, thanks)

03- HIT-136 mounted (please remove background of room, thanks)

04- Drill pilot holes (please remove background of room, thanks)

05- Door prepped (please remove background of room, thanks)

06- Adjusting for door thickness

07- Installing lock

08- Installing spacer bushing

09- Mounting outside escutcheon (please remove background of room, thanks)

10- Attaching motoring wiring

11- Attaching ribbon cable

12- Pulling wiring into outside escutcheon (please remove background of room, thanks)

13- Securing escutcheons

14- Installing levers

15- Installing batteries and battery cover (please remove background of room, thanks)

16- Finished installation outside escutcheon

17- Finished installation inside escutcheon

We Recommend