Converting An Omnilock OP2000 to a Wireless Access Management System OPW2000

For the third and final article in the OSI Wireless Access Management System (WAMS) series, we will convert an earlier model OMNILOCK electro-mechanical cylindrical leverset to be WAMS-capable. All OSI electro-mechanical systems manufactured after year...


To access the remainder of this piece of premium content, you must be registered with Locksmith Ledger. Already have an account? Login

Register in seconds by connecting with your preferred Social Network.

OR

Complete the registration form.

Required
Required
Required
Required
Required
Required
Required
Required
Optional
Required
Required

The primary differences between the OP2000 main circuit board and the OPW2000 main circuit board are as follows: The OP2000 main PCB (printed circuit board) has one large (approximately 1-square-inch) Phillips integrated circuit at the 3 o'clock position. It also has two integrated circuits that have white labels with OM/OP2000 typed on at least one of them. A two-screw terminal block is on the battery side of the OP2000 PCB at the 12 o'clock position. The OPW2000 PCB has a metal rectangular-shaped RF cover at the 8 o'clock position. It also has two metal cans (clock oscillators), one at the 10 o'clock and one at the 3 o'clock position. On the battery side of the OPW2000 PCB is large can (capacitor) at the 1 o'clock position.

INSTALLING THE WAMS ANTENNA

The next series of steps is to install the WAMS antenna. The WAMS antenna is necessary for the reader to be capable of communicating with the gateway.

Step 1. Carefully un-clip the plastic infrared window cover plate from the exterior housing.

Step 2. Slide the antenna wire and the metal connection plate from the outside through the opening made by removing the plastic cover plate.

Step 3. Pull the antenna wire through and position the ABS antenna cover flush with the face of the exterior housing.

Step 4. Using the interior steel mounting plate to keep the cap in place, install the two Phillips head Screws.

Step 5. Attach the male plug end of the antenna cable to the connector Jack J8 that is located almost dead center of the OPW2000 WAMS main circuit board.

INSTALLING THE CIRCUIT BOARD

The final series of steps is to install the WAMS equipped main circuit board.

Step 1. Position the main circuit board with the bottom resting against the two screw posts. In this position, there is sufficient wire and ribbon cable to make the connections.

Step 2. Attach the four-wire connector to the top left corner of the circuit board.

Step 3. Open the ribbon cable connector by pulling out on the outside clips. Slide the ribbon cable into the slot as far as it will go. Keep the end of the ribbon cable in the connector and push down on the two outside clips to secure the ribbon cable.

Step 4. Position the main circuit board in the exterior housing and install the two Phillips head screws with lock washers. Then install the threaded post. Make sure the main circuit board is securely mounted.

Step 5. Insert the lockset assembly into the housing assembly.

Step 6. Place the gasket attached battery cover and back plate onto the housing assembly. Install the four Phillips head back plate screws. The circuit board should still be accessible.

Step 7. Attach the two-wire red/black motor wire connector. If present, attach the two-wire yellow key bypass detection connector.

Step 8. Install the four AA batteries, from left to right, according to the diagrams.

Step 9. Press and hold the reset button on the circuit board approximately three seconds until the green light on the keyboard flashes. Allow the system to self-test.

The green light will flash five times, indicating the system is operational. A red flash indicates system malfunction.

Step 10. Position the battery cover and install the Phillips head screw.

The OSI OP2000 has been converted to the OPW2000 and is now ready to be installed on a door to control access.

Every OSI electromechanical lock can be upgraded to a higher level of security and/or method of controlling access. This provides the end-user the capability of upgrading without the expense of replacing the hardware.

The only exceptions are the OMNILOCK OM250 and the traditional OMNILOCK OM100-300-500 Series systems. These systems can NOT be upgraded to WAMS capability

A quick rule-of-thumb for determining WAMS upgrade compatibility is, “If the keypad buttons are Round, the system CANNOT be upgraded to WAMS capability. If the keypad buttons are Square, the system CAN be upgraded” to WAMS capability.

For more information contact your local locksmith wholesaler or OSI SECURITY DEVICES, Inc., 1580 Jayken Way , Chula Vista , CA 91911-4644 . Telephone: 619-628-1000. Fax: 619-628-1001. Website: www.omnilock.com.

Rick Rasmussen is VP of Sales at OSI Security Devices. An ex-Navy man, Rick spent some 20 years in the defense electronic and military intelligence-gathering community. He has lived abroad with his wife and two boys including a four-year government stint in Saudi Arabia . Rick now has a passion for locks and locking hardware.