Securitron System #05: Any exit door where free egress is permitted.
Outside Operation: Door is secured via the Magnalock. Entry is permitted using an optional entry device that releases the magnetic lock.
Inside Operation: Door is secured via the Magnalock. Free egress is accomplished by pushing on the TSB that de-energizes the lock. Note: Securitron System #05 has options using different locking mechanisms for different applications.

Securitron System #06: Two separate single door “Interlock” system, where high security or atmospheric integrity (Clean Room) is a must.
Outside Operation: Vestibule door #1 is closed and locked by the Magnalock. Entering an authorized user code on the keypad (or other switching device) will de-energize the lock and allow access into the vestibule. Once the first door  secures, the second door  can be accessed in the same manner.
Inside Operation: Door #2 is normally closed and locked by the Magnalock. Activation of the TSB will de-energize the lock and allow egress into the vestibule. Once the second door secures, the first door  can be used for egress in the same manner.

Securitron System #07: Three Door Interlock where high security or atmospheric integrity (Clean Room) is a must.
Outside Operation: Vestibule doors #1 and #2 are closed and locked by the Magnalock. Entering an authorized user code on the keypad (or other switching device) will de-energize the lock and allow access. Once the first or second door is secured, the third door is accessed in the same manner.
Inside Operation: Door #3 is normally closed and locked by the Magnalock. activation of the TSB will de-energize the lock and allow egress into the vestibule. Once door #3 secures, doors #1 or #2 can be used to egress in the same manner.

Securitron System #08: Public restrooms in parks and day use areas.
Outside Operation: Doors are unlocked during normal times of operation. Outside normal operation hours, the doors are locked by the Magnalock and access is gained by use of the key switch.
Inside Operation: Doors are unlocked during normal times of operation. Outside normal operation hours, egress is gained by use of the TSB.

Securitron System #09: Any exterior door where controlled access and free egress is required and there is a concern that the door might be blocked open against the will of the building owner or tenants. (i.e. secured parking, apartment and dorm buildings)
Outside Operation: Door is closed and locked by the Magnalock. Entering an authorized user code on the keypad (or other switching device) will de-energize the lock and allow access.
Inside Operation: Door is normally closed and locked by the Magnalock. TSB will de-energize the lock and allow egress. If the door is blocked or held open for longer than the time pre-set on the Door Prop Alarm (30 sec, 60 sec, 120 sec or 240 sec), an alarm will sound. The alarm will silence once the door is secured.

Securitron System #10: Utility or supply closet.
Outside Operation: Door is closed and locked by the Magnalock. Entering an authorized user code on the keypad will de-energize the lock and allow access.
Inside Operation: Door is closed and locked by the Magnalock. Depressing the Push Button (PB) will de-energize the lock directly and trigger the Request to Exit (REX) on the Digital Entry Keypad for a pre-programmed release period of 1-60 seconds to allow egress.

Securitron System #11:  Two door interlock with doors normally locked, with key switch for emergency override.
Outside Operation: Vestibule doors #1 and #2 are closed and locked by the Magnalock. Entering an authorized user code on the keypad (or other switching device) will de-energize the lock and allow access. Once door #1 secures, door #2 can be accessed in the same manner.
Inside Operation: Door #2 is normally closed and locked by the Magnalock. Activation of the TSB will de-energize the lock and allow egress into the vestibule. Once door #2 secures, door #1 can be used to egress in the same manner.